เครื่องตรวจสมรรถภาพปอด ดีที่สุด

EasyOne® Air

Portable & PC spirometer

EasyOne® Air is a flexible, accurate and proven spirometry solution designed for healthcare providers large and small. Utilizing TrueFlow™ technology, this portable spirometer delivers reliable results without the need for calibration to ensure lifetime worry-free operation. Thanks to the vivid color touch screen, it is easy to navigate, view real-time results and enter data.

  • Flexible Use, Consistent Results
    EasyOne® Air can be used as a portable or as a PC spirometer. It delivers consistent results regardless of setting or environmental factors.
  • Calibration-free TrueFlow™ Technology
    Utilizing high-quality components and Swiss precision-engineering, TrueFlow™ delivers robust and reliable testing results without needing calibration.
  • Color Touch Screen
    View real-time graphs, quickly enter patient data and easily navigate with the high resolution color touch screen in the EasyOne® Air.
  • Bluetooth and EMR Connectivity
    Easily connect to PC for real-time patient incentives, data exchange and EMR connectivity.

WHY NDD EasyOne Air?

Details
Ready to Take on Any Challenge

Regardless of location, environment or number of tests you will perform, EasyOne® Air will exceed your expectations.

  • Reliable design tried and tested at large screening events
  • Extremely robust TrueFlow™ measurement technology
  • Performs up to 100 complete tests with one battery charge
  • Proven completely calibration-free device

Infection Control
Avoid cross-contamination and reduce cleaning to an absolute minimum with the single-patient-use flow tube.

  • All parts exposed to patient’s breath are single use
  • Only simple surface cleaning needed
  • No contamination of sensor possible
  • No humidity can get into the device

Choose Between Portable Mode and PC
Use EasyOne® Air in portable mode, where the data is stored and the graph is displayed directly on the device, or use it in PC mode for more options.

  • Portable or PC mode
  • Stable Bluetooth connection
  • Real-time curve display
  • Real-time data transfer

 

 

 

Customized Reports
Customize reports and chose the parameters to be displayed.

  • Choose which graphs to be displayed
  • Color reports for better visibility
  • Arrange graphs and parameters through EasyOne Connect
  • Choose between Z-score, % predicted and LLN through EasyOne Connect

Connectivity to Printers, PCs and EMR
Easily integrate EasyOne® Air into your existing clinical workflow. The device is equipped with Bluetooth and USB modules making connections to printers, a central database and EMR systems extremely easy and stable.

  • Directly connect printers via USB or print via EasyOne Connect
  • Synchronize data via USB or Bluetooth
  • Integrate into all major EMR/EHR systems via HL7, XML, GDT, or API
  • Reference projects to all major EMR systems available on request

QC-Grading and Result Interpretation
Get automatic quality grading and interpretation based on NLHEP and ATS/ERS with the EasyOne® Air.

  • Quality grades based on NLHEP and ATS/ERS for all tests
  • ATS/ERS interpretation
  • GOLD/Hardie, NICE, JRS and NLHEP

TrueFlow™ - Trusted Ultrasound Technology
Stop worrying about calibration or accuracy of flow measurements. TrueFlow™ is the only ultrasound technology proven to be accurate for a lifetime for flow and volume measurements.

Large Selection of Predicted Sets (%Pred, Z-score and LLN)
The first in line for newly published predicted values: EasyOne® devices are used in predicted studies worldwide (e.g. LUNOKID, ALAT).

  • %Pred, Z-score, LLN
  • GLI (Stanojevic 2009, Quanjer 2012)
  • NHANES III (North America)
  • PLATINO (South America)
  • ERS (Europe) and JRS, IP, Chhabra (Asia), Thai2000 (Thailand)

Specifications

Standard and recommendations

Quality, Medical Devices & Electrical
ISO 13485 , ISO 14971, IEC 62366 ,IEC 62304 , ISO 26782, ISO 23747 ,IEC 60601-1, IEC 60601-2, ISO 10993-1
FDA
510(k) clearance
Associations & Institutes
ATS/ ERS 2005, NIOSH, OSHA

Languages

Available languages
English, French, German, Spanish

Technical

Printing options
Direct to printer or with EasyOne Connect software
Data management
EasyOne Connect
Export
HL7, XML, GDT, with software
Data links
USB, Bluetooth
Test storage
Up to 10‘000 tests
Age range
Spirometry > 4 years
Dimensions
87 x 155 x 36 mm (H x W x D), 356 g 3.4 x 6.1 x 1.4‘‘ (H x W x D), 13 oz
Device classification
Type BF applied part
Operating conditions
Temp 0 – 40 °C/ 32 – 104 °FRel. Humidity 5 – 90% Athmosph. Pressure 700 – 1060 hPa
Power supply
5 VDC, Standby 0.3W
Rechargeable battery
Exchangeable, 3.6 VDC

Parameters

FVC
BEV, EOTV, FEF10, FEF25, FEF 2575, FEF2575/FVC, FEF40, FEF50, FEF50/FVC, FEF60, FEF75, FEF80, FET, FET2575, FEV.25, FEV.5, FEV.5/FVC, FEV.75, FEV.75/FVC, FEV1, FEV1/FEV6, FEV1/FVC, FEV3, FEV3/FVC, FEV6, FVC, MEF20, MEF25, MEF40, MEF50, MEF60, MEF75, MEF90, MMEF, PEF, PEFT, t0

FVL

BEV, EOTV, FEF10, FEF25, FEF 2575, FEF2575/FVC, FEF40, FEF50, FEF50/FVC, FEF60, FEF75, FEF80, FET, FET2575, FEV.25, FEV.5, FEV.5/FVC, FEV.75, FEV.75/FVC, FEV1, FEV1/FEV6, FEV1/FIV1, FEV1/FVC, FEV3, FEV3/FVC, FEV6, FIF25, FIF50, FIF50/FEF50, FIF75, FIV.25, FIV.5, FIV1, FVC, MEF20, MEF25, MEF40, MEF50, MEF60, MEF75, MEF90, MIF25, IF50, MIF75, MMEF, PEF, PEFT, t0


SVC

ERV, IC, IRV, Rf, VC, VCex, VCin, VCmax, VT


MVV
MVV, MVV6, MVVtime, VT

Predicted Normal Values Spirometry

GLI
Stanojevic 2009, Quanjer 2012

North America
NHANES III (Hankinson) 1999, Knudson 1983, Knudson 1976, Crapo 1981, Morris 1971 & 1976, Hsu 1979,Dockery (Harvard) 1993, Polgar 1971, Gutierrez (Canada) 2004, Eigen 2001

Latin America
Pereira 1992, Perreira 2006 & 2008, Pérez-Padilla (PLATINO) 2006, Pérez-Padilla (Mexico) 2001,Pérez-Padilla (Mexico, Pediatrics) 2003, Chile 2010, Chile (Pediatrics) 1997

Europe
ERS (ECCS, EGKS, Quanjer) 1993, Zapletal 1977, Zapletal 2003, Rosenthal 1993, Austria 1988, Austria 1994,Sapaldia (Switzerland) 1996, Roca (Spain, SEPAR) 1982, Garcia-Rio (SEPAR) 2013, Vilozni 2005, Falaschetti 2004,Klement (Russia) 1986

Europe Scandinavia
Hedenström 1985 & 1986, Gulsvik (Norway) 1985, Berglund Birath (Sweden) 1963, Langhammer (Norway) 2001, Finnish 1982 (1998), Nystad 2002

Australia
Hibbert 1989, Gore Crockett 1995

Asia
Chhabra (India) 2014, Dejsomritrutai (Thailand) 2000, Indonesia 1992, IP (China, HongKong) 2000 & 2006,JRS 2001 & 2014

Africa
Ethiopia 1985

Flow/ Volume Sensor

Type                                                             Ultrasonic transit time

Flow Range                                                   ± 16 l/s

Flow Resolution                                           4 ml/s

Flow Accuracy (except PEF)                       ± 2% or 0.020 l/s

PEF Accuracy                                              ± 5% or 0.200 l/s

MVV Accuracy                                            ± 5% or 5 l/min

Volume Range                                              ± 12 l

Volume Resolution                                        1 ml

Volume Accuracy                                           ± 2% or 0.050 l

Resistance                                                     0.3 cm H20/l/s at 16 l/s